EICR Report

Why Do You Need to Test the EICR Report in London, UK?

Home Improvement Services

EICR Report is very important. Thousands of people in the UK are injured each year by electrical breakdowns. If you are a homeowner, you have a responsibility to make sure your belongings are safe. This was the beginning of the family power test.

  • Home power testing and inspection
  • 3 hour time frame
  • There will be a call 1 hour before arrival.
  • Certified by an experienced engineer

If you own a home in that country, you need to make sure the electrical equipment is safe, including if you own a home. The most important reason is to give the resident a sense of security in a safe environment, but it is also important to keep in mind that family insurance requires an EICR Report (test certificate) for electrical equipment. When you receive the policy

What do household EICR Report tests do?

Regular inspection of electrical equipment will ensure compliance with UK regulations. Tests to see if the electrical equipment or circuit is overloaded. Find out the potential hazards of electric shock and fire. Includes closure or lack of ground which can lead to safety issues. These examinations should be performed by a Landlord Certificate officer specialist. However, electricity can be dangerous. Especially if there is a fault in the electrical equipment!

Choose the best home electronics testing service in London.

If you need an electrical test at home, verify my ownership. With a response time of 3 hours, you can instantly inspect your electrical equipment. And we are confident that EICR Report will never lose sight of London in service and speed. We will call you an hour before your arrival. So you can plan your day with our fully qualified engineers tested and tested. We will be happy to discuss this with you at any stage of the process. So you know what’s going on EICR Report on the need for appropriate electrical equipment for homeowners and homeowners.

LEDs can provide the same day service to assist in emergency inspections and help move a new home / new customer. All engineers have the latest code testing and certification of the 18th edition as well as offer a full range of calibrated test kits and kits. You can contact the tenant or the agent. Get the keys from the real estate agent. Or adjust the time according to your convenience

Our regular test inspections include a thorough inspection of fixed wires and a full line of property tests, including:

  • Land connection between gas and water
  • The right consumer unit
  • Damage to electrical wires, sockets, switches and more.
  • Testing of complete bicycle tools
  • The 6 page report is edited using fast test software.

Two pages of the report are flagged as bugs and listed with C1 to C3 priorities. These numbers indicate the following conditions:

  • C1-Current Risk: Risk of Injury – Immediate Correction Needed.
  • C2- Possible corrective action- Urgent
  • C3 – Needs progress.
  • Additional verification is required.

The rate for the revision work will be reported with the VAT receipt for the revision. You can email the EICR Report to multiple settlers if needed to help with the home or new resident relocation process.

  • Regular inspection fees
  • Prices start at: £ 90 + VAT (1 bed stay – up to 10 circuits)
  • We also offer special rates to most homeowners and property tenants.
  • Fact file for regular testing

Wiring Principles Amendment Part 3 is the latest version of the IEE British Standard Edition. All the electronics we use are trained in IEE regulations and take review courses to use their skills. 

Our engineering team has at least 10 years of field experience working for LEDs.

1848 – Perform regular electrical inspections in England. To pass the City and Guild Level 3 Certificate in Electrical Installation Condition Report, Testing, and Certification (2391), you must attach EICR Report to your engineer. This training provides engineers with relevant information and procedures in addition to basic tests. Verification and visual verification This involves collecting accurate information about cable types, fuses, MCBs and more. Presence and proper operation of RCD travel switch to protect property and life from fire and electric shock. The presence and exact size of the property’s ground conductor. Uses metal parts that may require ground to supply main gas and water

This test includes equipment certification tests using the following tools:

  • Voltage tester for measuring bolts
  • Seventh Continuity Tester
  • Insulation resistance in M ​​ohm units
  • Ground loop amplifier tester for measuring ohms.
  • RCD tester for measuring MS

Complete testing of home / business equipment complying with IEEBS7671 wiring regulations, including fuse panels, grounding, wiring and installation hardware. And equipment (lights, sockets, switches, etc.), installation methods, flexible joints, and more.

  • Perform the following test.
  • Ground wire continuity
  • Continuation of the last conductor of the ring
  • Terminal
  • Installation resistance – to determine the arc or moisture between phases – phase ground
  • Ground Loop Obstacle – Check the ground path.

EICR Report test to check travel time and MA settings

The test consists of the consumer unit and the test circuit at the point. Includes property inspection and equipment testing. Consumer items are also certified to ensure good grounding and incorrect current flow. These tests are call Electrical Installation Condition Report. These tests ensure that the circuit has a continuous ground path to each joint and that the EICR Report operates at the specified time and current. Please contact us for more information. Because we can help with any technical queries you may have.